CATEGORY 5e 350 CABLE

Components:

  Conductor:  

24 AWG Solid Bare Copper
.0208” NOM OD

Insulation:

 

FEP
.035” NOM OD
.0073” AVG Wall

Pairing:
 

The components are twisted into pairs with varying left hand lays to minimize crosstalk. Four pairs are then cabled together using a left hand lay.

Pair#

Color

Pair#

Color

1

BLU+WHT/BLU

2

ORN+WHT/ORN

3

GRN+WHT/GRN

4

BRN+WHT/BRN

Overall Jacket:



 

Low Smoke PVC Medium               Blue
.180” NOM OD
.015” AVG Wall
 
A ripcord is pulled under jacket

Agency Approvals:




 

Underwriters Labortaories, Inc. type CMP, communications plenum cable, listed as being suitable for use in ducts, plenums, and other spaces used for environmental  air.  Also listed as having adequate fire-resistant and low smoke producing charateristics, in accordance with article 800 of the national electrical code.

Category 5e 350 Cable
Worst Case Electrical Characteristics

 Characteristic Impedance:

100 ± 15Ω (0.772-100.0 MHz)

Maximum Conductor Resistance:

9.38Ω/100 Meters @ 20° C

Maximum Resistance Unbalance:

5%

Maximum Mutual Capacitance:

5.6 nF/100 Meters @ 1 kHz

Maximum Capacitance Unbalance:

330 pF/100 Meters

Maximum Delay Skew:

25 ns/100 Meters

Frequency
 

Insertion
Loss
Max.

NEXT Loss
Min.
(dB/100 m)

ACR
Min.
(dB/100 m)

ELFEXT
Min.
(dB/100 m)

Return
Loss
Min.

Delay
Max.

(MHz)

(dB/100 m)

WP

PS

 WP

PS

WP

PS

(dB/100 m)

(ns/100 m)

.0772

1.8

73.0

70.0

71.2

68.2

72.0

69.0

----

----

1.0

2.0

71.3

68.3

69.3

66.3

69.8

66.8

20.0

570

4.0

4.1

62.3

59.3

58.2

55.2

57.7

54.7

23.0

552

8.0

5.8

57.8

54.8

52.0

49.0

51.7

48.7

24.5

547

10.0

6.5

56.3

53.3

49.8

46.8

49.8

46.8

25.0

545

16.0

8.2

53.3

50.3

45.0

42.0

45.7

42.7

25.0

543

20.0

9.3

51.8

48.8

42.5

39.5

43.7

40.7

25.0

542

25.0

10.4

50.3

47.3

39.9

36.9

41.8

38.8

24.3

541

31.25

11.7

48.9

45.9

37.2

34.2

39.9

36.9

23.6

540

62.5

17.0

44.4

41.4

27.4

24.4

33.8

30.8

21.5

539

100.0

22.0

41.3

38.3

19.3

16.3

29.8

26.8

20.1

538

  155.0*

28.1

38.5

35.5

---

---

25.9

22.9

18.8

537

200.0*

32.4

36.8

33.8

---

---

23.7

20.7

18.0

537

250.0*

36.9

35.3

32.3

---

---

21.8

18.8

17.3

536

300.0*

41.0

34.2

31.2

---

---

20.2

17.2

16.8

536

350.0*

44.9

33.2

30.2

---

---

18.9

15.9

16.3

536

400.0*

48.5

32.3

29.3

---

---

17.7

14.7

15.9

536

 

Frequencies beyond TIA and ISO requirements are for information only.

†Discrete values are for information only.  Equations for swept frequencies govern limits

The impedance values above reflect actual input impedance data.  Meets international requirements for non-filtered input impedance.  this cable exceeds the requirements of TIA/EIA-568-B.2 for CATEGORY 5e and is swept tested through 400 MHz.  HI-NET 350

ENHANCED CATEGORY 5e CABLES provide a worst case headroom of +6dB over current TIA and ISO standards for next loss, psnext loss, elfext and pselfext.

botline2 

For Top Quality
E-Mail or Call us Today !

Corporate Overview | Products and Services | Wireless | Cable Specifications & Partnerships
Cat5e 350 Cable | Category 3 Riser Type Cable | Fiber Optic J-Interlock Dist
 Category 6 Plus Cable | Category 5e Cable | Inquiries | Contact Us | Home

Copyright  2022, Metro Cable and Networks.  All Rights Reserved.